Portables
Gas detectors

Building on from the success of our new partnership with Crowcon, we are proud to be launching their portable gas detector range. Crowcon’s portable gas detectors protect against a wide range of industrial gas hazards with both single gas and multi gas monitors available. With a variety of sizes, complexities and certifications, our customers can find the right portable gas detection solution to meet the number and type of gas sensors you need to protect your people and the environment.

Large industrial gas pipelines in a modern refinery at sunrise 3d render

MULTI-GAS DETECTORS

T4x

T4x is Crowcon’s zone 0 approved personal protection solution for detecting the four most common gas hazards:

Carbon Monoxide (CO)

Hydrogen Sulphide (H2S)

Flammable Gases (MPS)

Oxygen Depletion (O2)

Now with improved detection of pentane, hexane and other long chain hydrocarbons.

Offering you compliance and low cost of ownership in a simple to use solution. The large single button and intuitive menu system allows T4x to be operated wearing gloves with minimal training.

T4x is durable by design and includes an integrated rubber boot as standard. An optional clip-on filter cover, which is easily removed and replaced, ensures sensors are protected in the dirtiest environments. Drop tested to 4m and well protected from water ingress through IP65 and IP67 certification, T4x allows uninterrupted working in the most demanding environments.

SizeW135 x H80 x D35 mm (5.3 x 3.1 x 1.4in)
Weight282g (9.9oz)
DurabilityDrop tested to 4m onto concrete
AlarmsAudible >95dB
Bright red/blue visual LEDs
Integrated vibrating alert
DisplayFront mounted, backlit. Optional 180° flip for easy viewing whilst worn
Logging130 hours of data logging; Up to 3500 events
BatteryRechargeable Li-ion
Up to 18 hour typical runtime (Standard sensor option)Up to 35 hours runtime (MPS and LLO2 options)
5.5 hour recharge
Operating temperature-20°C to +55°C (-4°F to +131°F)*
Humidity10 to 95% RH @ 40°C non-condensing
Ingress protectionIndependently tested to IP65 and IP67
ApprovalsATEX and UKCA II 1 G Ex ia IIC T4 Ga -20°C ≤ Ta ≤ +55°C (T4 Type 1)

 

IECEx Ex ia IIC T4 Ga -20°C ≤ Ta ≤ +55°C (T4 Type 1)

UL and cUL: Use in hazardous locations Class 1 Div 1 groups A,B,C,D only as to intrinsic safety

MED Directive 2014/90/EU (Pending)

InterfaceUSB communications lead
AccessoriesIncluded with T4:

 

Integrated alligator clip and tethering loop

Bump/Calibration plate

Available separately:
Single unit cradle charger, 10 unit cradle charger; Vehicle charger
Clip on filter plate for sensor protection in dusty environments
I-Test automated bump and calibration station

T4

T4 is Crowcon’s personal protection solution for detecting the four most common gas hazards:

Carbon Monoxide (CO)

Hydrogen Sulphide (H2S)

Flammable Gases 

Oxygen Depletion (O2)

Offering you compliance, robustness and low cost of ownership in a simple to use solution. The large single buttonand intuitive menu systemallows T4 to be operated wearing gloves with minimal training.

Crowcon’s toughest portable yet, T4 is durable by design and includes an integrated rubber bootas standard. An optional clip-on filter cover, which is easily removed and replaced, ensures sensors are protected in the dirtiest environments. Drop tested to 4m and well protected from water ingress through IP65 and IP67 certification, T4 allows uninterrupted working in the most demanding environments.

Now with improved detection of pentane, hexane and other long chain hydrocarbons.

T4 contains a wide range of powerful features to make everyday use easier and safer:

SizeW135 x H80 x D35 mm (5.3 x 3.1 x 1.4in)
Weight282g (9.9oz)
DurabilityDrop tested to 4m onto concrete
AlarmsAudible >95dB
Bright red/blue visual LEDs
Integrated vibrating alert
DisplayFront mounted, backlit. Optional 180° flip for easy viewing whilst worn
Logging130 hours of data logging; Up to 3500 events
BatteryRechargeable Li-ion
18 hour typical runtime
5.5 hour recharge
Operating temperature-20°C to +55°C (-4°F to +131°F)*
Humidity10 to 95% RH @ 40°C non-condensing
Ingress protectionIndependently tested to IP65 and IP67
ApprovalsATEX and UKCA: II 2 G Ex db ia IIC T4 Gb Tamb -20°C to +55°C (T4 Type 2)

 

IECEx: Ex db ia IIC T4 Gb -20°C ≤ Ta ≤ +55°C (T4 Type 2)

UL and cUL: Use in hazardous locations Class 1 Div 1 groups A,B,C,D only as to intrinsic safety

INMETRO: Ex db ia IIC T4 Gb -20 °C ≤ Ta ≤ +55 °C

MED: Directive 2014/90/EU

StandardsEMC Directive 2014/30/EU
InterfaceUSB communications lead
AccessoriesIncluded with T4:

 

Integrated alligator clip and tethering loop

Bump/Calibration plate

Available separately:
Single unit cradle charger, 10 unit cradle charger; Vehicle charger
Clip on filter plate for sensor protection in dusty environments
I-Test automated bump and calibration station

Gas-Pro

The Gas-Pro portable multi gas detector offers detection of up to 5 gases in a compact and rugged solution. It has an easy-to-read top mount display making it easy to use and optimal for confined space gas detection.

An optional internal pump, activated with the flow plate, takes the pain out of pre-entry testing and allows Gas-Pro to be worn either in pumped or diffusion modes.

Size43 x 130 x 84mm (1.7 x 5.1 x 3.3ins)
Weight309g 4 gas (10.8oz)/ 340g pumped (11.9oz)

 

333g 5 gas (11.7oz)/ 362g pumped (12.7oz)

AlarmsAudible >95dB @ 30cm (98dB @30cm in loud mode)
Visual – all angle dual red/blue LEDs
Vibrating alert
DisplayTop mount for ease of view with dual colour backlight (green/red)
Data logging125hr at 10-second intervals (45,000 logs)
Event loggingAlarm, over range, calibration, bump, on/off, TWA, 1000 events
BatteryRechargeable Li-ion, >14hr (13 hours pumped operation) based on CH4, O2, H2S, CO
Typical charge time 7.5hr
SamplingInternal pump as option
Operating temperature-20°C to +55°C (-4°F to +131°F)
Storage -20°C to +65°C (-4°F to +149°F)
Humidity10 to 95% RH+
Ingress protectionIndependently tested to IP65 and IP67
ApprovalsIECEx: Ex db ia IIC T4 Gb Tamb -20°C to +55°C
ATEX: II 2 G Ex db ia IIC T4 Gb Tamb -20°C to +55°C
UL: Class 1, Division 1, Groups A, B, C, and D UL 913, UL 60079-0 and UL 60079-11
INMETRO: Ex db ia IIC T4 Gb Tamb -20°C to +55°C
Marine Equipment Directive: MED 1500009
ComplianceFCC and CE. Complies with EMC Directive 2014/30/EU, EN50270 and EMC FFC CFR 47 Part 15, ICES-003
InterfaceData connection for gas test solutions and direct to PC
ChargingDirect connection to multi-regional power supply
Vehicle charger adaptor
Desktop cradle
USB power and communications lead

 

Gas-Pro IR

The infrared measurement gives improved reliability and measures gas in two different wavelengths: one that absorbs gas and the other does not. With little chance of being poisoned, the Gas-Pro IR personal multi gas detector is inherently safer and saves the need of regular and expensive pellistor replacement when used in likely contaminated environments.

The Gas-Pro personal multi gas detectors are known for their simple use and functionality as well as easy testing and calibration. The Gas-Pro IR now completes the Gas-Pro range and gives greater flexibility for sensor selection in this 5-gas multigas detector.

Size43 x 130 x 84mm (1.7 x 5.1 x 3.3ins)
Weight309g 4 gas (10.8oz)/ 340g pumped (11.9oz)
333g 5 gas (11.7oz)/ 362g pumped (12.7oz)
AlarmsAudible >95dB @ 30cm (98dB @30cm in loud mode)
Visual – all angle dual red/blue LEDs
Vibrating alert
DisplayTop mount for ease of view with dual colour backlight (green/red)
Data logging125 hr at 10-second intervals (45,000 logs)
Event loggingAlarm, over range, calibration, bump, on/off, TWA, 1000 events
BatteryRechargeable Li-ion, >14 hr (13 hr pumped operation) based on CH4, O2, H2S, CO
Typical charge time 7.5 hr
SamplingInternal pump as option
Operating temperature-20°C to +55°C (-4°F to +131°F)
Storage-20°C to +65°C (-4°F to +149°F)
Humidity10 to 95% RH
Ingress protectionIndependently tested to IP65
ApprovalsIECEx: Ex db ia IIC T4 Gb Tamb -20°C to +55°C
ATEX: II 2 G Ex db ia IIC T4 Gb Tamb -20°C to +55°C
UL: Class 1, Division 1, Groups A, B, C, and D UL 913, UL 60079-0 and UL 60079-11
INMETRO: Ex db ia IIC T4 Gb Tamb -20°C to +55°C
Marine Equipment Directive: MED 1500009
ComplianceFCC and CE
Complies with EMC Directive 2014/30/EU
EN50270 and ICES-003
InterfaceData connection for gas test solutions and direct to PC
ChargingDirect connection to multiregional power supply
Vehicle charger adaptor
Desktop cradle
USB power and communications lead

 

Gas-Pro PID

The Gas-Pro PID VOC monitor utilises the Photo Ionization Detection technology to allow you to detect hundreds of Volatile Organic Compounds (VOCs). If you are working in an environment that is high in levels of solvents, glues, paints and general VOCs, the Gas-Pro PID will monitor your safety. With its dual-coloured display, the monitor will alert the user with its 95db audible alarm and its dual-coloured visual alarm bars.

Size43 x 130 x 84mm (1.7 x 5.1 x 3.3ins)
Weight309g 4 gas (10.8oz)/ 340g pumped (11.9oz)
333g 5 gas (11.7oz)/ 362g pumped (12.7oz)
AlarmsAudible >95dB @ 30cm (98dB @30cm in loud mode)
Visual – all angle dual red/blue LEDs
Vibrating alert
DisplayTop mount for ease of view with dual colour backlight (green/red)
Data logging125hrs at 10-second intervals (45,000 logs)
Event loggingAlarm, over range, calibration, bump, on/off, TWA, 1000 events
BatteryRechargeable Li-ion, >14 hours (13 hours pumped operation) based on CH4, O2, H2S, CO
Typical charge time 7.5 hours
SamplingInternal pump as option
Operating temperature-20°C to +55°C (-4°F to +131°F)
Storage-25°C to +65°C (-13°F to +149°F)
Humidity10 to 95% RH
Ingress protectionIndependently tested to IP65
ApprovalsIECEx: Ex db ia IIC T4 Gb Tamb -20°C to +55°C
ATEX: II 2 G Ex db ia IIC T4 Gb Tamb -20°C to +55°C
UL: Class 1, Division 1, Groups A, B, C, and D UL 913, UL 60079-0 and UL 60079-11
INMETRO: Ex db ia IIC T4 Gb Tamb -20°C to +55°C
Marine Equipment Directive: MED 1500009
ComplianceFCC and CE
Complies with EMC Directive 2014/30/EU
EN50270 and ICES-003
InterfaceData connection for gas test solutions and direct to PC
ChargingDirect connection to multiregional power supply
Vehicle charger adaptor
Desktop cradle
USB power and communications lead

 

Gas-Pro TK

Gas-Pro TK dual range portable monitor measures the concentration of flammable gas in inerted tanks. Available for methane, butane and propane, Gas-Pro TK uses a dual IR sensor – the best technology for this specialist environment, which means Gas-Pro TK dual IR:

Auto-ranges switch between %vol and %LEL measurement, so always operating to the correct parameter.

Measures gas in high %vol as well as %LEL concentration, which single IR sensors can’t

Isn’t inhibited by high hydrocarbon concentrations unlike catalytic bead sensor

Gas-Pro TK keeps you up-to-the moment with oxygen concentrations in the tank; telling you when the oxygen levels are;

Low enough to load and store fuel safely;

High enough for safe tank entry.

Tanks can be sampled quickly from their top, middle or base, due to an integrated pump which draws samples through a line up to 30m long.

Offering detection of up to five gases in a compact and rugged solution, Gas-Pro TK has an easy-to-read top mount display, combining ease of use and user focused features. At 340g, it is light enough to clip to your belt or overalls, so it easy for the technician to keep with them during their working day.

Size43 x 130 x 84mm (1.7 x 5.1 x 3.3ins)
Weight340g (11.9oz)
AlarmsAudible 95dB
Visual – all angle dual red/blue LEDs
Vibrating alert
DisplayBright top mounted display can be viewed while worn
Data logging125hr at 10-second intervals (45,000 logs)
Event logging1000 events
BatteryRechargeable Li-ion, 13 hour typical runtime (4 sensors, pump running)
Typical charge time 7.5hr
SamplingInternal pump with 30m draw
Operating temperature-20°C to +55°C (-4°F to +131°F)
Humidity10 to 95% RH non-condensing
Ingress protectionIndependently tested to IP65 and IP67
ApprovalsIECEx: Ex db ia IIC T4 Gb Tamb -20°C to +55°C
ATEX: II 2 G Ex db ia IIC T4 Gb Tamb -20°C to +55°C
UL: Class 1, Division 1, Groups A, B, C, and D UL 913, UL 60079-0 and UL 60079-11
INMETRO: Ex db ia IIC T4 Gb Tamb -20°C to +55°C
Marine Equipment Directive: MED 1500009
ComplianceFCC and CE. Complies with EMC Directive 2014/30/EU, EN50270 and EMC FFC CFR 47 Part 15, ICES-003

 

Custom Solutions for each application

SINGLE GAS DETECTORS

Clip SGD

Easy to maintain

Changeable Alarm Levels– ensures compliance with changing regulations or company procedure

Clip SGD Docking Station – keeps monitors correctly configurated without service or technical team

‘Bump Test Due’ Indication – alerts the user and team members that the monitor is not compliant and requires a bump test.

User friendly

Compact And Lightweight – non-intrusive and comfortable to wear – perfect for any length of shift

Single Button Operation – delivers simplicity for users and reduces training time

Efficient

Wide Operating Temperature Range– an effective personal gas detector for a wide range of harsh environments

Water And Dust Resistant to IP66 and IP67

Size91 x 54 x 32mm (3.6 x 2.1 x 1.3ins)
Weight93g (2.7oz) toxic, 104g (3.7oz) O2
AlarmsTop, front and side visual LEDs
90 dB audible alert at 10cm
Vibrate
T90 Response Time< 30 seconds
TemperatureH2S -30°C to + 50°C (-40°F to +122°F)

 

CO  -30°C to + 50°C (-40°F to +122°F)

O2  -30°C to + 50°C (-30°F to +122°F)

Humidity15% to 95% non-condensing RH
Event loggingMost recent 30 events
Ingress protectionIP66 and IP67
TestsSelf test on activation and every 20hrs: continuous automatic battery integrity tests
Operational life2 years > 2900 alarm minutes*
Shelf life6-month shelf life prior to activation
Shown on box label
ComplianceEMC Directive 2014/30/EC, FCC CFR 47 Part 15, IECES-003
CertificationUL-913 & CSA-C22.2 No.157
Class 1 Div 1 & 2, Groups A, B, C and D, T4
ATEX II 1G Ex ia IIC T4 Ga
IECEx Ex ia IIC T4 Ga
Warranty2 years from activation*
Sensor rangeH2S – 0-100ppm

 

CO – 0-300ppm

O2 – 0-30% vol.

Gasman

The Gasman is a rugged, compact single gas detector, designed for use in the toughest environments. Its compact and lightweight design makes it the ideal choice for industrial gas detection, in oil and gas, chemical plants (with exotic gases), steel works (special CO sensor), hospitality (CO2), renewable energy (hydrogen) and waste and water works. Weighing just 130g, it is extremely durable, with high impact resistance and dust/water ingress protection, loud 95 dB alarms, a vivid red/ blue visual warning, single-button control and an easy-to-read, backlit LCD display to ensure clear viewing of gas level readings, alarm conditions and battery life. Data and event logging are available as standard, and there is a built-in 30 day advance warning when calibration is due.Gasman is also available in a safe area CO2version offering 0-5% carbon dioxide measurement.

Size90 x 48 x 24 mm (3.5 x 1.9 x 0.95 ins)
WeightFlammable: 138g (4.9oz)
Toxic: 85g (3oz)
Oxygen: 129g (4.6oz)
Carbon monoxide: 139g (4.9oz)
Typical response times (T90)Flammable: 20s
Flammable (MPS): 17s
Toxic gas: 20s
Oxygen: 10s
Oxygen (Long-Life): 10s
AlarmsAudible: 95dB; Multiple alarm options let you select distinctive tones for different alarm levels
Visible: Dual colours red/ blue flashing LEDs in a gas hazard
Internal vibrating alarm
DisplayCustom LCD with backlight, with display of gas concentration. Graphic symbols for battery (with proportional indication of remaining operation time), and display mode. Start up indication when calibration is due within 30 days, calibration overdue or service required.
Normal display: Real time gas concentration levels
Display recall: Peak readings and TWA
Data loggingFull timed datalogging with adjustable sample rate, set to 1 min. data rate as default.
900 hours storage at 1 min. interval (54,000 logs), >4800 events
BatteryRechargeable lithium battery for all gas types
Non-rechargeable lithium battery for toxics and oxygen (excluding CO2)
Operating time*Rechargeable with MPS: >3days
Rechargeable: 12 hours minimum for flammable unit
Non-rechargeable: Up to 2 years
 Sampling Optional manual aspirator
Operating temperature**-20°C to +65°C (-4°F to +149°F)
Humidity5 – 95% RH
0 to 99% RH (O2 LL MPS)
Ingress protectionIP65
ApprovalsEurope: Toxic or O2: ATEX II 1G Ex ia IIC T4 Ga (-20°C ≤ Ta ≤ +65°C) BASEEFA04ATEX0384
Flammable: ATEX II 2G Ex ia db IIC T4 Gb (-20°C ≤ Ta ≤ +65°C) BASEEFA04ATEX0383Flammable (MPS): ATEX II 1G Ex ia IIC T4 Ga (-20°C ≥Ta ≥ +65°C) BASEEFA04ATEX0383
International: Toxic or O2: IECEx Ex ia IIC T4 Ga (-20°C ≤ Ta ≤ +65°C) BAS05.0039
Flammable: IECEx Ex db ia IIC T4 Gb (-20°C ≤ Ta ≤ +65°C) BAS05.0038
North America: CSA Class 1 Groups A,B,C,D Division 1
StandardsEurope: EN60079-0, EN60079-11, EN60079-1, ATEX 2014/34/EU
North America: CSA22.2, 152EN50270, EN50271, EN61779, EN45544
PC InterfaceRS232 connection from interface module in charger
RS232/USB converter available
CalibrationGasman can be routinely calibrated using Portables PC software or by using Checkbox IMH
AccessoriesGasman is supplied with an integral alligator clip.

 

Optional accessories:

Gas test kit, Gasman external filter, leather carry case, single way charger, charger interface software and communication kit (excluding PSU), 5 way multi-charger

 

Custom solutions for each application

This site is registered on wpml.org as a development site.